Fluke Networks
We are the worldwide leader in certification, troubleshooting, and installation tools for professionals who install and maintain critical network cabling infrastructure. From installing the most advanced data centers to restoring telephone service after a disaster, our combination of legendary reliability and unmatched performance ensure jobs are done efficiently. Visit us at https://www.flukenetworks.com
-
06:46 Popular
Damaged Cable Causes A Return Loss Failure (DTX CU 203) - By Fluke Networks
Added 266 Views / 0 LikesIf you see a return loss failure happen at the lower frequencies it's very likely that you have a cable issue. This video demonstrates how your DTX Cable Analyzer can diagnose a return loss problem caused by a cable issue. To learn more visit: http://www.
-
04:31 Popular
DSX 5000 CableAnalyzer The 4 DB Rule: By Fluke Networks
Added 320 Views / 0 LikesThe 4 dB rule applies to return loss measurements. When looking at the graph where the limit line is black, this is where the insertion loss is less than 4 dB and per are standards we ignore all measurements where the insertion loss is less than 4 dB. Lea
Featured -
02:17 Popular
DSX 5000 CableAnalyzer 10% Length Rule: By Fluke Networks
Added 243 Views / 0 LikesThis video explains the DSX 5000 CableAnalyzer 10% length rule. Learn more about the DSX-5000 CableAnalyzer™ here - http://www.flukenetworks.com/datacom-cabling/Versiv/dsx-cableanalyzer-series Request a demo here - http://www.flukenetworks.com/content/req
-
01:36 Popular
Clearing The Memory And All Settings In Your OptiFiber Pro (OFP 102): By Fluke Networks
Added 229 Views / 0 LikesThis video will show you how to restore your OptiFiber Pro back to it's default conditions. This is going to wipe all of your custom setting. Learn more about OptiFiber® Pro OTDR at http://www.flukenetworks.com/datacom-cabling/fiber-testing/optifiber-pro-
-
04:32 Popular
Badly Made Cable Causes A Return Loss Failure (DTX CU 205) : By Fluke Networks
Added 234 Views / 0 LikesWhen we get a return loss failure reading, it could be cause by a cable issue or the tool is able to tell you if there is something else happening in the cable system you are monitoring. To learn more visit: http://www.flukenetworks.com/datacom-cabling/co
-
05:38 Popular
Bad Termination Causes A NEXT Failure (DTX CU 201) - By Fluke Networks
Added 293 Views / 0 LikesYour DTX Cable Analyzer has the ability to monitor and locate sources across your entire cabling system. In the example we are going to analyze cross talk due to a bad cable termination. To learn more visit: http://www.flukenetworks.com/datacom-cabling/co
-
11:36 Popular
Testing SC To SC Duplex Fibers (DTX FI 104) - By Fluke Networks
Added 366 Views / 0 LikesThis video discusses how to get consistent, reliable test results when testing SC to SC Duplex Fibers. To learn more visit: http://www.flukenetworks.com/datacom-cabling/copper-testing/dtx-cableanalyzer-series?ls=yt
Featured -
05:15 Popular
Certifying A Cat 6A Patch Cord (DTX CU 103): By Fluke Networks
Added 214 Views / 0 LikesIn the demonstration it will explain how to certify a 6A patch cord. Also, in the example we will go over how it is done incorrectly for learning purposes. To learn more visit: http://www.flukenetworks.com/datacom-cabling/copper-testing/dtx-cableanalyzer-
-
13:05 Popular
Testing ST To ST Duplex Fibers (DTX FI 105) - By Fluke Networks
Added 375 Views / 0 LikesThis video discusses how to certify an ST - ST duplex fiber link using the DTX cable analyzer and the optional series two fiber modules with the interchangeable adapters. To learn more visit: http://www.flukenetworks.com/datacom-cabling/copper-testing/dtx
Featured -
01:53 Popular
Recover Deleted Results From A DTX CableAnalyzer (DTX CU 105): By Fluke Networks
Added 284 Views / 0 LikesAt some point while testing you may want to look back at previously deleted search results on your DTX Cable Analyzer. This is not a reliable resource and is undocumented and unsupported - but can be used as a last resort to recover data. To learn more vi
-
07:37 Popular
Certifying Testing An M12 Patch Cord (DTX CU 104) - By Fluke Networks
Added 229 Views / 0 LikesIn this video we demonstrate how to certify an m12 patch cable correctly and how to certify it incorrectly. To learn more visit: http://www.flukenetworks.com/datacom-cabling/copper-testing/dtx-cableanalyzer-series?ls=yt
-
03:42 Popular
Lubricant Causes Insertion Loss Failure (DTX CU 206) - By Fluke Networks
Added 263 Views / 0 LikesBecause lubricant is conductive it can affect what happens to the electrons in a cable causing insertion loss failure. This video shows you how to diagnose this issue using the DTX CableAnalyzer. To learn more visit: http://www.flukenetworks.com/datacom-c
-
04:40 Popular
Cable Causes A NEXT Failure (DTX CU 202) - By Fluke Networks
Added 300 Views / 0 LikesThis video discusses how your DTX cable analyzer has the ability to figure out whether a near end crosstalk failure was caused by a cable or a termination issue and walks you through the steps to figure that out. To learn more visit: http://www.flukenetwo
Featured -
01:41 Popular
Restoring The DTX CableAnalyzer Back To Its Factory Default (DTX CU 107) - By Fluke Networks
Added 239 Views / 0 LikesThis video demonstrates how to reset your DTX CableAnalyzer back try its original condition. To learn more visit: http://www.flukenetworks.com/datacom-cabling/copper-testing/dtx-cableanalyzer-series?ls=yt
-
05:23 Popular
Water In The Cable Causes A Return Loss Failure (DTX CU 204) - By Fluke Networks
Added 303 Views / 0 LikesThis video demonstrates how to diagnose water in the cable and how to find out locate where the water is in the cable. To learn more visit: http://www.flukenetworks.com/datacom-cabling/copper-testing/dtx-cableanalyzer-series?ls=yt
Featured -
1:30:34 Popular
Relatórios De Certificação - Parte 1
Added 197 Views / 0 LikesSerá que você sabe interpretar corretamente um relatório de Certificação? Nesta série de 2 webinars vamos tentar te ajudar a dominar todos os detalhes desta tarefa tão pouco ensinada. Na parte 1 falaremos sobre os testes de Cobre.
-
49:54 Popular
Relatórios De Certificação Parte 2 20180816 1206 1
Added 204 Views / 0 LikesSerá que você sabe interpretar corretamente um relatório de Certificação? Nesta série de 2 webinars vamos tentar te ajudar a dominar todos os detalhes desta tarefa tão pouco ensinada. Na parte 2 falaremos sobre os testes de Fibra.
-
00:45 Popular
Une Reduction Des Erreurs : Raison N° 3 - Par Fluke Networks
Added 205 Views / 0 LikesConfigurez la référence de fibre de manière incorrecte et vous risquez de re-tester chaque lien. Mais avec l'assistant de définition de référence Versiv, vous pouvez éliminer ce problème.
-
00:52 Popular
Des Tests Plus Rapides : Raison N° 2 - Par Fluke Networks
Added 193 Views / 0 LikesArrêtez d'attendre et commencez à tester. Versiv démarre plus rapidement et teste plus rapidement que votre ancien testeur. Vous économiserez de l'argent et rentrerez chez vous plus tôt.
-
01:22 Popular
FROM THE TAC-Testing A Category 8 Link With The DSX-8000 By Fluke Networks
Added 293 Views / 0 LikesJoin Fluke Networks’ Regional Marketing Engineer Jim Davis in our Technical Assistance Center as he demonstrates testing a Category 8 link using the DSX-8000 CableAnalyzer™